Model | Single-channel Infusion pump WIT-601A |
Communication ( Optional) | WIFI Capabilities, with communication protocol Interface for information system |
Warmer (Optional) | Warmer on the side of pump to keep the medical liquid warm |
Drug Library | Library size configurable: More than 500 drugs &54 drug dose unit |
History Records | Up to 20,000 infusion records |
Data Transfer | RS485 port, Wired interface connectable with PC to upload& download data . |
Display | High brightness color LCD 3.2inch screen , Adjustable brightness. |
Infusion Mode | Rate/VTBI 、Time/VTBI 、Rate/Time 、Volume 、Drop 、Micro 、Simple Rate、 Programmable 、DOSE Weight 、Drug lib 、Auto Bolus 、Manual Bolus. |
Programmable | 8 programmable sequences of ‘ Time & Flow rate & VTBI’ |
IV SET | 10d/ml 、15d/ml 、20d/ml 、60d/ml (diameter≈3.4mm - 4.5mm) IV tube can be used Open system for all brands of IV tube More than 50 brands IV tube feature data can be stored inside the pump. |
Accuracy Error | Volume Mode :≤ ±5% | Drop Mode :≤ ±2% |
Calibration | Automatic or manual calibration ; |
Flow Rate | Volume:0. 10ml/h~1200ml/h | Drop:1d/min~400d/min |
Flow rate increment | 0.1ml/h |
VTBI | 0. 1~9999.9 ml |
Total Volume | 0.1~9999.9ml |
KVO | Default:1ml/h ; & 1ml/h~20ml/h can be set. |
Purge | 600ml/h |
BOLUS | Keep pushing down ‘blous’ button to run the default bolus parameters. Or click the ‘bolus’ button to enter the bolus parameter editable interface. |
Upstream pressure | High / Middle / Low, or OFF |
Downstream pressure | 20 pressure Levels: 200mmHg - 1200mmHg ( mmHg & kPa) |
Bubble | Detected by ultrasonic sensor with adjustable 5 levels, 50μL ~ 800μL, |
Drop Sensor | Infrared sensor to detect the drops, monitoring the infusion status |
Alarms | Audio and Visual alarm for : Bubble, Door open, Finish, Pause timeout, Down Occlusion, Up Occlusion, Lower Battery or damage, Motor error, Incorrect IV Set-type, Pressure test failure, Motor failure, Abnormal drop rate, Heater failure and etc. 30 kinds safety monitoring alarm |
Self -detection | 2 CPU systems; Self-detection at startup and running time |
Non-interrupt | Parameters can be modified when pump running |
Keypad Lock | Automatically or Manually lock the keyboard |
AC Power | AC100V ~ 240V ,50Hz/60Hz ,25VA; &Vehicle-mounted power supply adapter ( Optional) |
Battery | NI-MH battery,DC9.6V, 2000mAh ( Roughly work 6hours at 25ml/h rate after fully charged) |
Electrical Safety Class | Class I, Type CF, IPX4 |
Install | Vertical (horizontal) IV Stand Pole |
Weight &Dimension | 2.0Kg; 130mm×120mm×195mm |
Working Environment | 5℃ ~ 40℃; 20% ~ 90% humidity; 70kPa ~ 106kpa atmospheric |
Application | Medical locations such as intensive care unit, pediatric ward, obstetrics and gynecology department for constant speed intravenous infusion of drugs |